Release 1.5.1 (July 17, 2009)
In this section Live Update Features Bug fixes Known issues |
See also Release 1.5.2 (August 3rd, 2009) Release 1.5.0 (January 20, 2009) Release 1.4.4 (September 11, 2008) Release 1.4.3 (September 5, 2008) Release 1.4.2 (May 13, 2008) Release 1.4.1 (February 4, 2008) Release 1.4.0 (December 19, 2007) Release 1.2.6 (July 9, 2007) Release 1.2.5 (September 25, 2006) Release 1.2.4 (July 24, 2006) Release 1.2.3 (April 18, 2006) Release 1.2.2 (April 13, 2006) Release 1.2.1 (April 8, 2006) Release 1.2 (March 9, 2006) Release 1.1.3 (October 24, 2005) Release 1.1.2 (October 17, 2005) Release 1.1 (September 12, 2005) Release 1.0.2 Release 1.0.1 Release 1.0 Patch 1 Release 1.0 |
Live Update
Sometimes, more up-to-date release notes are available online. Click here to download the latest version from the Peavey Oxford website, then press F5 to refresh the display.
Features
NWare
Support for nControl units
Support for ControlMatrix TPU devices
You can now add ControlMatrix TPU 2 and TPU 4 devices to your design. These allow you to work with ControlMatrix telephone paging units. The new devices are located under Hardware in the NWare device tree.
For information on the TPU 2 and TPU 4, refer to the Products page on the MediaMatrix website.
New Comms Processor device
The device tree includes a new Comms Processor device under Control / Tools. This allows you send and receive textual data over a serial or TCP connection. In TCP mode, the device operates as a Telnet TCP client, initiating connections using a specified IP address and port. While the device can initiate outgoing connections, it is not capable of accepting incoming connections and cannot operate as a TCP server.
Notes:
- This device is not supported in Emulation mode.
- If you use the NioNode RS-232 port, it must be configured so that console mode is disabled. For more information on console mode, see Specifying the function of the RS-232 serial port in the NION Hardware Manual.
- When you use TCP mode, the role containing the Comms Processor can be deployed to any NioNode in your project. This is because a TCP connection can be made from any NioNode on the network to the receiving device. When you use a serial connection, however, the receiving device must be physically connected to a particular NioNode. You must therefore deploy the role to this NioNode and not any other in the project.
For more information, see Comms Processor in the NWare Device Reference.
NION
FTP server for copying media files
You can now copy audio files to NioNodes on the network and from NioNodes to other locations using FTP.
You can quickly change the available media in your project by copying new files to the NioNode. You can also minimize the size of the NWare project file by storing your media on the NioNode and not in the project file itself.
For more information, see Copying media files to and from a NION in the NION Hardware Manual.
Regular updating of time zone definition files
This release includes updated time zone definition files to ensure that the time zone settings are correct for each locality where NIONs are used.
All subsequent releases of NION and nControl firmware will include the most up-to-date time zone definition files.
nControl
The new nControl unit has been released. For more information, refer to the nControl Hardware Manual.
nTouch 180
The new nTouch 180 has been released. For more information, refer to the nTouch 180 Hardware Manual.
Bug fixes
NION
390 - Tonal noise was produced when AES Input connectors were removed
Previously, when you removed an input connector from an AES card, a significant level of tonal noise was produced. This problem has now been fixed.
392 - NION stopped functioning when role containing three or more AES cards was stopped
Previously, if you created an NWare project containing three or more AES cards and then deployed the role to a NION, it ran successfully. However, if you then attempted to redeploy it, the NION stopped functioning.
393 - Daylight saving time was displayed instead of standard time
The time displayed in the NION web interface was always daylight saving time, even when the current date did not fall within the period when daylight saving time is used. This has now been fixed so that the correct time is always shown for the current time zone.
400 - Null characters stopped data being read from serial port via Python
In previous versions, if you used a Python script to read data from the NION serial port and a null character was encountered, the data stream was terminated. This limitation has now been removed, and null characters, which are valid, can be read from the serial port.
Tip: You can also use Python script to read null characters from the serial port on an nControl unit.
Known issues
NWare
57 - Additional steps needed for non-admin users running NWare under Windows XP
Currently, non-administrator users cannot run NWare or Kiosk without additional steps being completed after the installation.
The administrator must change the permissions of the \program files\mediamatrix\nware <version>\plugins\nware\xml folder to allow write access for the non-administrator users. Once this has been done, NWare and Kiosk will operate normally.
For more information, see Allowing non-admin users to run NWare and Kiosk in the NWare User Guide.
379 - Cannot uninstall via Control Panel under Windows Vista
385 - Selecting undo after adding certain devices causes NWare to close unexpectedly
If you drag a device from the device tree over to the page, open the device block, and then press CTRL+Z to undo the operation, in the case of certain devices, NWare will close unexpectedly.
Note: This does not occur when adding all types of devices, but we recommend avoiding this exact sequence of steps as a precaution.
404 - Page locking feature prevents a project from being edited
If you use the page locking feature, it is possible that NWare will not allow you to view the different pages in your project or add devices to the project. We have seen this problem occur in the following scenario:
- A new NWare project is created.
- A new page is added next to the default page and then it is locked (and automatically hidden).
- The new page is shown again.
- The first page is deleted.
- The project is saved and then reloaded.
No page tabs are available, so different pages cannot be viewed or edited.
408 - Playback of some audio files via CHIMP not possible under Windows Vista
If you attempt to play audio files using the CHIMP option on the Wav File Recorder, no audio can be heard from the PC headphones. This problem does not occur under Windows XP – it is a Vista-only issue.
416 - XDAB channel limit not working correctly
If you drag an XDAB device over to the page, the Virtual XDAB Properties dialog box is displayed. If specify a channel count value greater than 448, then display the advanced settings, override the normal channel limit and specify a new limit, when you close the Advanced properties dialog box and then the Virtual XDAB Properties dialog box, a warning message is displayed and the device cannot be created.
420 - Command Prompt window displayed when loading project under Windows 7 Beta
If you double-click an npa file to open it, the file is opened in NWare as expected, but a Command Prompt window is also displayed.
421 - NWare Kiosk display flickers when switching between tabs
If you add the setting <hide_root_tab value = "true"/>
to the Kiosk personality file to hide the page tabs in your design, and your project contains a button that switches to a new page, the display will flicker when the button is clicked.
nControl
414 - nControl time setting advances one hour of what is specified
When all the NION and nControl units on the network are set to use normal mode for time synchronization, if you change the time on the nControl unit via the web interface, the time is advanced by one hour from what is specified.