RS-485 Configuration |
|
Enable |
Enable the use of RS-485. Notes:
|
Unicast Address |
Prevents multicast RS-485 data connections across the network. Only Unicast connections to a single destination may be established. |
Format |
Set to 9 bit. The 9th data bit is bridged over the Ethernet along with the standard 8 data bits. This value cannot be changed. |
Baud Rate |
Baud rate for data transmission and reception in bits per second. Set to 38400. This value cannot be changed. |
Rx MAC |
MAC address of the CobraNet Interface from which SCI data will be accepted. This may be any multicast address except 01:60:2B:FD:00:00 through 01:60:2B:FD:FF:FF, which have been reserved by Cirrus Logic for use as asynchronous global channels. |
Tx MAC |
MAC address of the CobraNet interface to which serial data is sent. May be any multicast or unicast address. |
RX Channel |
The number of the receive channel to which this CAB belongs. This CAB will be able to receive serial data from other CABs transmitting on this channel. |
TX Channel |
The number of the transmit channel to which this CAB belongs. This CAB will be able to transmit serial data to other CABs receiving on this channel. |
PPeriod |
The polling period for devices attached to the serial port. The time in milliseconds that elapses after a device has been polled before it is polled again. |
See also Slot x: 4 Channel Line Input (black) Slot x: 4 Channel Mic Input (green) Slot x: 4 Channel Line Output (blue) |